3 TECHNICAL FEATURES
ELECTRICAL FEATURES
Power
Supply voltage 10 to 30 Vdc
Power consumption max. 1.4 W + scanner
USER INTERFACE
LED indicators Power ON, Warning,
Tx (RS485 Multipdrop activity)
PHYSICAL FEATURES
Mechanical dimensions 161 x 114.5 x 40 mm (6.34 x 4.51 x 1.57 in)
Weight about 340 g. (12 oz.)
SOFTWARE FEATURES
Parameter storage Non-volatile internal memory
ENVIRONMENTAL FEATURES
Operating temperature
-10 to 50
°C (14 to 122 °F)
Storage temperature
-20 to 70
°C (-4 to 158 °F)
Humidity max. 90% non condensing
Vibration resistance
EN 60068-2-6
14 mm @ 2 to 10 Hz;
1.5 mm @ 13 to 55 Hz;
2g @ 70-200 Hz
2 hours on each axis
Shock resistance
EN 60068-2-27
30g; 11 ms;
3 shocks on each axis
Protection class
IP64
(when correctly connected to the scanner)