Symbologies
118 PowerScan
®
PD7100 Corded
UPC-A — cont.
In-Store Minimum Reads
This feature specifies the minimum number of consecutive times an in-store label must
be decoded before it is accepted as good read.
In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as
well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting
with the three characters '980'.
ENTER/EXIT PROGRAMMING MODE
In-Store Minimum Reads = 1
In-Store Minimum Reads = 2
In-Store Minimum Reads = 3
In-Store Minimum Reads = 4
DEFAULT