SC6000Reference Manual
42 31 6 5Figure 2 - SC6000-1200 Standard Model Connector Panel Modem Connector 1 Power/Net Connector2 Main Interface Connector3 Ethernet C
GUIDE TO INSTALLATION The following can be used as a checklist to verify all the steps necessary to complete installation of the SC6000 Controller.
x
INTRODUCTION 11 INTRODUCTION 1.1 PRODUCT DESCRIPTION The new SC6000 Controller offers all the necessary functions to make the phases of installatio
SC6000 1 1.3 LED INDICATORS 21 Figure 6 - LEDs Description Power ON and Communication LEDs1 Status LEDs 2 System Signal LEDs Name Color State
INTRODUCTION 11.4 ACCESSORIES The following accessories are necessary to build a reading station based on SC6000 (the scanner-related accessories are
SC6000 2 2 INSTALLATION To install the system follow the given procedure: 1) Select the mounting location and mount the SC6000 Controller; 2) Mount
INSTALLATION 22.2 OVERALL DIMENSIONS 319.5 [12.58]248.7 [9.79]80.2 [3.16]99.7 [3.93]124.4 [4.90]39.7 [1.56]MØ839.7 [1.56]124.4 [4.90]298 [11.73] mm i
SC6000 2 2.3 MECHANICAL MOUNTING To mount the SC6000 Controller on the reading station frame proceed as follows: 1 Mount the bracket on the reading
INSTALLATION 2The specially punched steel ring has been designed to obtain the most precise rotation possible in terms of angle calibration, steadines
SC6000 2 2.4 ELECTRICAL CONNECTIONS The connectors available for each scanner model are the following: Scanner Model Connector Type Power/Net 25-
INSTALLATION 22.4.2 Ethernet Connector This connector is available for all SC6000 Controller models and allows the Ethernet connection to the host.
SC6000 2 Ethernet Interface The Ethernet interface (NIC) can be used for TCP/IP communication with a remote or local host computer by connecting the
INSTALLATION 22.4.3 DeviceNet Connector The 5-pin male connector is only available in the SC6000-1215 DeviceNet model and allows connection between
SC6000 2 2.4.4 Profibus Connector The 9-pin female Profibus connector (white) is only available in the SC6000-1211 Profibus model and allows connecti
INSTALLATION 22.5 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations, but also require the correct setup of the so
SC6000 2 Figure 23 - Modem Connection 2.5.2 Fieldbus Network The SC6000 can be connected to a Fieldbus network (Ethernet, Profibus and DeviceNet)
INSTALLATION 2 Figure 25 - Dual Ethernet Connection 2.6 KEYPAD AND DISPLAY The SC6000 keypad allows entering a menu to select one of the functions
SC6000 2 Reading Performance Window This window displays the following data: • Number of the processed parcels • Good Read Rate • No Read Rate • M
SOFTWARE CONFIGURATION 33 SOFTWARE CONFIGURATION 3.1 GENIUS™ INSTALLATION Genius™ is a new Datalogic scanner configuration tool providing several i
SC6000 REFERENCE MANUAL
SC6000 3 2. From the Device Menu select Local Device Network Settings and configure your SC6000 as Master (SYNCHRONIZED is the default value), as sho
SOFTWARE CONFIGURATION 3Each device is indicated by the following graphical objects: • check box allowing to select/deselect a specific device to pe
SC6000 3 Proceed with the network setup by using one of the icons available on the Tool Bar according to the procedure to follow: = Net-Autoset pro
SOFTWARE CONFIGURATION 3Network Wizard Before performing this procedure, a Lonworks address must be assigned to each slave scanner. The most practica
SC6000 3 2. If desired, select a slave scanner within the "Current Devices" area and click on the icon (or select the "Show Device&quo
SOFTWARE CONFIGURATION 33.2.2 Alternative Slave Address Assignment As alternatives to Network Setup through the Master, each Slave scanner can be as
SC6000 3 4) From the Device Menu select Local Device Network Settings and configure your SC6000 as Other, as shown in the figure below: Figure 30 –
SOFTWARE CONFIGURATION 36) Configure the Common Slave Scanner parameters according to your application using the Lonworks Slave Common Parameters bra
SC6000 3 • Selecting the codes to be read in the Code Definition folder (they must be the same as those set for the slave scanners) • Set-up the c
SOFTWARE CONFIGURATION 33.4 PARAMETER DEFAULT VALUES The following table contains the list of the factory default settings for the SC6000 Controller
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy SC6000 Reference Manual Ed.: 10/2005
SC6000 3 Parameter Default SettingOperating Modes Operating Mode Selection Packtrack Physical Encoder Enabled Encoder Step (hundredths of millimet
SOFTWARE CONFIGURATION 3Parameter Default SettingAuxiliary Serial Port Data TX Enabled (checked) Pass Through Disabled (checked) Parameters Baud
SC6000 3 Parameter Default SettingOutput 3 Line State Normally Open Activation Event None Alternative Activation Event None Deactivation Event No
MAINTENANCE 44 MAINTENANCE 4.1 DATALOGIC AUTOMATIC REPLACEMENT PROCEDURE (DARPTM) Once the system configuration has been completed, launch the DAR
SC6000 4 In case of SC6000 failure proceed as follows: Figure 33 - Removing the Compact Flash 1. Disconnect the device 2. Remove the rubber cove
TROUBLESHOOTING 55 TROUBLESHOOTING NOTE Before contacting your local Datalogic office or Datalogic Partner or ARC, it is suggested to save the devi
SC6000 5 TROUBLESHOOTING GUIDE Problem Suggestion Communication (Ethernet): the Ethernet LED is not lit. • Verify the HUB connection. • Verify Geniu
TECHNICAL FEATURES 66 TECHNICAL FEATURES ELECTRICAL FEATURES Supply voltage 15 to 30 Vdc Power consumption 6.5 W typical 9 W Max. (including start
SC6000 A A ALTERNATIVE CONNECTIONS REFERENCE POWER SUPPLY - I/O (POWER/NET CONNECTOR) The PWO supplies 24 VDC. 25-pin D-Sub Female Connector Pino
ALTERNATIVE CONNECTIONS REFERENCE ALonworks SC6000 242523LON_IN A LON_IN B SHIELD_IN 13242523LON ALON BSHIELDLON_OUT A LON_OUT B SHIELD_OUT 12111312
CONTENTS REFERENCES ...v Reference Docume
SC6000 A VPS/PS AUX ENCODER GroundSC6000 A/B B/A GND VS_INPUTS*Signal PWO VS VSPSIN + 5V ~~+- *VS_INPUTS is connected through the 25-pin Extended I/O
ALTERNATIVE CONNECTIONS REFERENCE AMAIN INTERFACE The main serial interface is compatible with the following electrical standards: RS232 RS485 full-d
SC6000 A SC6000 8 RTSRTS PWOGND-ISO5 CTS7 RX 3 RX TX 2 TX Shield Host Signal Ground CTS Figure 40 - RS232 Connections RS485 Full-Duplex Interface
ALTERNATIVE CONNECTIONS REFERENCE AEXTENDED I/O 25-pin D-Sub Male Connector Pinout Pin Name Function 1 VS_OUTPUTS Power for outputs 2 IN1 A Inpu
SC6000 A VUSER INTERFACE GroundSC6000A/B B/A GND VS_INPUTS Signal PWO Figure 44 - PNP Command Input Using System Power VUSER INTERFACE GroundSC60
ALTERNATIVE CONNECTIONS REFERENCE ABy default, OUT1 is associated with COMPLETE READ event, which activates when the code has been read correctly. In
SC6000 A MODEM SC6000 offers a dedicated 9-pin port for a Modem connection. The modem connection allows a Host to remotely control the reading statio
GLOSSARY Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in machine-readable form. The general fo
Scanner A device that examines a printed pattern (barcode) and either passes the uninterpreted data to a decoder or decodes the data and passes it on
INDEX A Accessories; 3 C Connector Pinouts; 36 Connectors DeviceNet; 11 Ethernet; 9 Profibus; 12 D DARPTM; 31 DeviceNet; 11 E Electrical Connection
Main Interface...39 Extended I/O...
DATALOGIC S.p.A., DATALOGIC S.p.A., 05Via Candini, 2 Via Candini, 2 40012 - Lippo di Calderara 40012 - Lippo di Calderara Bologna - Italy Bologna -
REFERENCES REFERENCE DOCUMENTATION The documentation related to the SC6000 is listed below: • PWO power supply unit • Document about the Etherne
SAFETY REGULATIONS POWER SUPPLY - This product is intended to be installed by Qualified Personnel only. WEEE COMPLIANCE vi
GENERAL VIEW SC6000 Controller 2 45 6 1 3 Figure 1 - General View Connector Panel Power On and Communication LEDs Connector Panel Legend