Installation Manual©2001-2007 Datalogic Mobile S.r.l.822000381 (Rev. B)08/07www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Li
INTRODUCTION 1 1 INTRODUCTION 1.1 DESCRIPTION OF STARGATE™ STARGATE™ is a radio base station that enables a wireless network allowing data transmi
STAR H GATE™ 1 Features Benefits • Seamless Active Roaming • Wide area coverage • Up to 2.000 RF devices supported Gryphon™ Mobile series
INTRODUCTION 1 1.2 PACKAGE CONTENTS The STARGATE™ Radio Base Station package contains: − n. 1 STARGATE™ Radio Base Station; − n. 1 STARGATE™ instal
STAR H GATE™ 1 1.4 RESET BUTTON This button deletes all RAM data restoring the last saved configuration. By pressing it for 2.5 seconds the yellow
INSTALLATION 2 2 INSTALLATION 2.1 POSITIONING STARGATE™ Before connecting the STARGATE™ base station, it is first necessary to position it so that
STAR H GATE™ 2 2.1.2 Wall Mounting Before performing the following operation, mount the fixing plate on the STARGATE™ bottom surface by means of the
INSTALLATION 2 For wall mounting, fix the related plate as follows: Set - screw Mounting holes Fixing plate guide Figure 3 - Wall Mounting Base 1.
STAR H GATE™ 8 3 3 CONNECTIONS STARGATE™ can be connected to the PC through an RS232 or an RS485 line. It is possible to set the base station by se
CONNECTIONS 3 Pinout 81 Figure 5 - RJ45 Modular Connector 987654321 Figure 6 - 9-pin Female Connector The cable connecting the base station to the
STAR H GATE™ 3 Figure 8 - RS485 Connection The cables, converter and power supplies are listed with their order number: A. 94A054000 2 m serial ca
Installation Manual©2001-2007 Datalogic Mobile S.r.l.822000381 (Rev. B)08/07www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Li
CONNECTIONS 3 CAUTION To configure the STARGATE™ base station use the cable and the adapter listed in par. 3.1. For further details see par. 4.3.
STAR H GATE™ 3 If connecting up to 16 STARGATE™ base stations in the same system, it is necessary to use a custom cable having two different pinouts d
CONNECTIONS 3 If using a shielded cable, it is necessary to link the cable shields together (see Figure 12) and connect them to the earth ground in o
STAR H GATE™ 14 3 3.3 RS485 CONNECTION USING STAR-BOX™ Several STARGATE™ base stations can be chained together in an RS485 network or a single STA
CONNECTIONS 3 Network Termination The RS485 bus must be properly terminated by positioning a jumper in both the last STAR-Box™ device and the first
STAR H GATE™ 4 4 CONFIGURING AND TESTING STAR-System™ 4.1 STAR-System™ OVERVIEW Two different layouts are provided depending on the application n
CONFIGURING AND TESTING STAR-System™ 4 If the system has been started correctly (invoking the proper STAR-Link™ ActiveX method) and the network initi
STAR H GATE™ 4 NOTE Be careful when installing two separate networks having overlapping RF coverage areas. In this case no RF device nor STARGATE™
CONFIGURING AND TESTING STAR-System™ 4 Example If working with an installation composed of 4 point-to-point cordless systems (RF device with its bas
STAR H GATE™ 4 4.2 LOADING A SW APPLICATION ONTO AN RF TERMINAL The following procedure is not valid for STARGATE™ USA model. This example explains
Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy STARGATE™ Ed.: 08/2007 ALL RIG
CONFIGURING AND TESTING STAR-System™ 4 6. If the downloading procedure has completed successfully (after a series of messages about automatic tests h
STAR H GATE™ 4 4.3 RS232 LAYOUT This procedure is intended to be a step-by-step guide explaining how to configure a STARGATE™ RF Base Station by usi
CONFIGURING AND TESTING STAR-System™ 4 10. Set the STARGATE™ (European models only) new address on the RF terminal (loading a software application
STAR H GATE™ 4 4. Select the Base stations option from the Settings menu: the RF Base stations dialog box appears; 5. Digit 2000 in the Edit box posi
CONFIGURING AND TESTING STAR-System™ 4 19. If the RS485 network is connected through a serial port different from the one previously used to configu
STAR H GATE™ 4 4.5 NOTES FOR THE PROGRAMMER STARGATE™ does not carry out continuous polling, but it is only enabled each time an RF device sends it
CONFIGURING AND TESTING STAR-System™ 4 Both the transactions (1 way and 2 way) must have an acknowledgement back to be completed correctly. This assu
STAR H GATE™ 5 5 TROUBLESHOOTING PROBLEMS CAUSES REMEDY STARGATE™ is not powered. Supply STARGATE™. The connecting cable is broken or it is not cor
TECHNICAL FEATURES 6 6 TECHNICAL FEATURES Electrical Features Micro-controller 16bit CMOS Program memory 128 Kb Data memory 128 Kb Supply voltage
Datalogic Mobile S.r.l. Datalogic Mobile S.r.l. 07Via S. Vitalino 13 Via S. Vitalino 13 40012 - Lippo di Calderara 40012 - Lippo di Calderara Bologn
CONTENTS COMPLIANCE... iv Radio Compliance...
Installation Manual©2001-2007 Datalogic Mobile S.r.l.822000381 (Rev. B)08/07www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Li
COMPLIANCE This device must be opened by qualified personnel only. RADIO COMPLIANCE Information for the User ENGLISH Contact the competent auth
FCC COMPLIANCE Modifications or changes to this equipment without expressed written approval of Datalogic could void the authority to use the equipm
WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barra
éviter les retombées négatives pour l'environnement et la santé dérivant d'une élimination incorrecte récupérer les matériaux dans le
GENERAL VIEW AB C D E F Figure 1 - STARGATE™ Key: A) Antenna B) LED C) Power supply connector D) Reset/downloading mode button E) RS232 conne
Comentarios a estos manuales