SOFTWARE CONFIGURATION
113
8
The following examples show some of the typical conditions occurring during the installation:
Under-exposure:
To correct this result it is recommended to change the following parameters in their order of
appearance:
1. increase the Exposure Time
2. increase the Gain
NOTE
In general, a longer exposure time corresponds to a lighter image but is
susceptible to blurring due to code movement. Exposure time is also
limited by the Internal Lighting mode parameter. Longer esposure times
can be set if the power strobe level is lowered.
High gain settings may produce a grainy image that may affect the
decoding process.
Figure 120 - Example Under Exposure: Too Dark