Datalogic Scanning MAGELLAN 3200VSI Manual de usuario Pagina 113

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 200
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 112
GS1 DataBar Expanded / Expanded Stacked
Product Reference Guide
105
GS1 DataBar Expanded / Expanded Stacked — continued
GS1 DataBar Expanded Length 1, Length 2 Programming Instructions
1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing
the length in decimal notation.
4. Scan the START/END bar code.
NOTE
For GS1 DataBar Expanded bar codes, only the
data characters are included in the length calcu-
lations.
START / END
PROGRAMMING bar codes
DEFAULT SETTING FOR THIS FEATURE: 01
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 74
³
Vista de pagina 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 199 200

Comentarios a estos manuales

Sin comentarios