www.datalogic.comDS1500Reference Manual
GENERAL VIEW DS1500 2 1 3 4 56 7 9 1011 8 Figure A 1 2 3 4 8765Mounting Holes Good Read LED External Trigger/Ready LED Tx Data/Active LED Las
GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the DS1500 scanner
xii
INTRODUCTION 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The new DS1500 industrial laser scanner is the combination of extremely compact dimension and
DS1500 1 1.2 APPLICATIONS DS1500 target applications are primarily OEM integration in application characterized by space constraints, demanding readi
INTRODUCTION 1 1.4 INDICATORS The five LEDs indicate the following: LED Standard Mode Test Mode Restore Double RS232 POWER ON (green) (Figure A,
DS1500 1 1.5 TEST KEY FUNCTIONING DS1500 provides an external key, which can be used for the following: - Restoring dual RS232 interface at power
INTRODUCTION 1 1.5.2 Activating Test Operating Mode To launch the Test Mode by the external key, proceed as follows: 1. From any operating mode, pr
DS1500 1 NOTE The Test Mode is not permanently saved. NOTE You must not be in Test Mode activated by Test Key when configuring DS1500 parameters.
INSTALLATION 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS1500 reader and all the parts supplied with the equipment are present and inta
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy DS1500 Reference Manual Ed.: 11/2007 AL
DS1500 2 2.2 MECHANICAL INSTALLATION DS1500 can be installed to operate in different positions. The two screw holes (M2 x 4) on the body of the reade
INSTALLATION 2 3.2 [0.13]3.2 [0.13]=11 [0.43]6 [0.24]=62 [2.44]20 [0.79]25 [0.98]1.5 [0.06]inchmm7.1 [0.28]31.8 [1.25]31.8 [1.25]25.1 [0.99]12 [0.47]
DS1500 2 2.2.1 Mounting DS1500 Using the DS1500 mounting bracket you can obtain the most suitable position for the reader as shown in the figure belo
INSTALLATION 2 2.3 ELECTRICAL CONNECTIONS All DS1500 models are equipped with a cable terminated by a 15-pin male D-sub high-density connector for co
DS1500 2 2.3.1 Power Supply Power can be supplied to the scanner through the pins provided on the 15-pin connector used for communication with the ho
INSTALLATION 2 RS232 Interface The serial interface is used in this case for point-to-point connections; it handles communication with the host compu
DS1500 2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-po
INSTALLATION 2 RS485 Half-Duplex Interface The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols. It can be
DS1500 2 Figure 10 shows a multidrop configuration with DS1500 scanners connected to a Multiplexer. CAUTION To avoid any possible Ground loop, keep
INSTALLATION 2 2.3.3 Auxiliary RS232 Interface The auxiliary serial interface is used exclusively for RS232 point-to-point connections. The paramet
CONTENTS REFERENCES ... v Conventions ...
DS1500 2 Code Verifier If the DS1500 is used as a Code Verifier, it is possible to indicate to the scanner what code to store as the verifier code th
INSTALLATION 2 An anti-disturbance hardware filter is implemented on the External Trigger input (< 5 milliseconds delay). An additional 15 ms (ty
DS1500 2 2.4 USER INTERFACE The following table contains the pinout for standard RS232 PC Host interface. For other user interface types please refer
INSTALLATION 2 2.5 POSITIONING The DS1500 scanner is able to decode moving barcode labels at a variety of angles, however significant angular distort
DS1500 2 The Tilt angle is represented by the value T in Figure 17. Position the reader in order to minimize the Tilt angle. TFigure 17 - Tilt Angl
INSTALLATION 2 2.6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to option
DS1500 2 In this layout the data is transmitted to the Host on the main serial interface. Host Mode programming can be accomplished through the main i
INSTALLATION 2 2.6.2 Pass-Through Pass-through mode allows two or more devices to be connected to a single external serial interface. Each DS1500 tr
DS1500 2 2.6.3 RS232 Master/Slave The RS232 master/slave connection is used to collect data from several scanners to build either a multi-point or a
INSTALLATION 2 2.6.4 Multiplexer Layout Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface.
3 READING FEATURES... 28 3.1 Advanced Code Builder (ACB)...
DS1500 3 3 READING FEATURES 3.1 ADVANCED CODE BUILDER (ACB) In addition to linear reading, the Advanced Code Builder (ACB) allows code reading by
READING FEATURES 3 ACB Readable ACB is disabled by default but can be enabled for the following code types: • Code 25 Interle
DS1500 3 3.1.2 Tilt Angle Improvement with ACB ACB allows barcode reading with an increased tilt angle. The tilt angle depends upon the code aspect
READING FEATURES 3 3.2.1 Step-Ladder Mode If scanning is perpendicular to the code motion direction (Figure 23), the number of effective scans perfor
DS1500 3 3.2.2 Picket-Fence Mode If scanning is parallel to the code motion, the number of effective scans is given by the following formula: SN = [
READING FEATURES 3 3.3 PERFORMANCE The DS1500 scanner has the following performances: Version Max Code Resolution Speed mm (mils) scans/s 1100
DS1500 3 3.4 READING DIAGRAMS DS1500-1100 2 1 0 1 5 4 3 2 3 4 5 (in) 0 1 32 106(in) 45 7 890 20 40 60 80 100 120140160180200220240260(mm) 12010080
READING FEATURES 35 3 DS1500-2100 1 0.5 0 0.5 2.5 2 1.5 1 1.5 2 2.5 (in) 01 53(in) 240 10 20 30 40 50 60708090100110120130(mm) 60 50 40 3020100102
DS1500 4 4 MAINTENANCE 4.1 CLEANING Clean the laser beam output window periodically for continued correct operation of the reader. Dust, dirt, etc
TROUBLESHOOTING 5 5 TROUBLESHOOTING 5.1 GENERAL GUIDELINES When wiring the device, pay careful attention to the pin number of the signals. If you
REFERENCES CONVENTIONS This manual uses the following conventions: “User” or “Operator” refers to anyone using a DS1500. “Device” refers to the DS
DS1500 5 TROUBLESHOOTING GUIDE Problem Suggestions Power On: the “Power On” LED is not lit Is power connected? If using a power adapter (like PG 220
TROUBLESHOOTING 5 TROUBLESHOOTING GUIDE Problem Suggestions Reading: Not possible to read the target barcode (always returns No Read) Check synchron
DS1500 6 6 TECHNICAL FEATURES ELECTRICAL FEATURES Input Power Supply voltage 5 Vdc ± 5% Power consumption max. 2 W Serial Interfaces Main RS23
TECHNICAL FEATURES 6 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES * EAN/UPC * Code 93 EAN/UPC (including Add-on 2 and Add-on 5) * Code 128 * 2/5
DS1500 A A DEFAULT CONFIGURATION The following table shows the default values of the Standard Application Program configuration Parameters. Paramet
DEFAULT CONFIGURATION A Parameter Default SettingAdvanced Code Options Linear Reading Options Required Quiet Zone Both ACB Parameters Max Scan Gap
DS1500 A Parameter Default SettingAuxiliary Interface Parameters Communication Mode Local Echo Baud Rate 9600 Parity None Data Bits 8 Stop Bits 1
DEFAULT CONFIGURATION A Parameter Default SettingData Format (continued) Data Packet Separator 2 <LF> Terminator 1 <CR> Terminator 2
DS1500 A Parameter Default SettingReading Parameters Beam Shutter Triggered Overflow Automatic Overflow Ratio 7 Motor Control Speed_4 Serial Motor
GLOSSARY ACB (Advanced Code Builder) Advanced Code Builder (ACB) allows code reading by “stitching” together two partial reads of it. ACB is effect
SAFETY REGULATIONS LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to
meaningful data and provides the interface to other devices. The decoder is normally integrated into the scanner. EAN European Article Number System
Pitch Rotation of a code pattern about the X-axis. The normal distance between center line or adjacent characters. See pars. 2.2.1 and 2.5. Position
Step-Ladder orientation When the barcode’s bars are positioned horizontally on the product, causing them to appear as a ladder. The ends of all bars
INDEX A Accessories; 6 Advanced Code Builder; 28 Applications; 2 C Cleaning; 35 E Electrical Connections; 11 Auxiliary RS232 Interface; 17 Inputs;
DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l., Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that
www.datalogic.comDS1500Reference Manual
Warning labels indicating exposure to laser light and the device classification are applied onto the body of the scanner (Figure A, 6). Warning and
CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be
DEUTSCH Benutzerinformation bezüglich Richtlinie 2002/96/EC der europäischen Kommission Am Ende des Gerätelebenszyklus darf das Produkt nicht über d