Datalogic-scanning F734-E Manual de usuario

Busca en linea o descarga Manual de usuario para Escáneres Datalogic-scanning F734-E. Datalogic Scanning F734-E User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
F734-E Series Terminals
User's Manual
©2001 - 2010 Datalogic Mobile S.r.l.
01/10
822000114 (Rev. E)
www.mobile.datalogic.com
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561
World wide Sales Network
available from: www.mobile.datalogic.com/contacts
Vista de pagina 0
1 2 3 4 5 6 ... 51 52

Indice de contenidos

Pagina 1 - F734-E Series Terminals

F734-E Series TerminalsUser's Manual©2001 - 2010 Datalogic Mobile S.r.l.01/10822000114 (Rev. E)www.mobile.datalogic.comDatalogic Mobile S.r.l.Via

Pagina 2

come si eviterebbe qualsiasi altra sorgente di luminosità intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi di un

Pagina 3

ATTENTION L'utilisation de procédures ou réglages différents de ceux donnés ici peut entraîner une dangereuse exposition à lumière laser visib

Pagina 4

RADIO COMPLIANCE Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of you

Pagina 5 - REFERENCES

FCC COMPLIANCE This compliance refers only to the F734-E batch model. Modifications or changes to this equipment without the expressed written appr

Pagina 6 - SAFETY REGULATIONS

WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barr

Pagina 7 - LASER SAFETY

Information aux utilisateurs concernant la Directive Européenne 2002/96/EC Au terme de sa vie utile, le produit qui porte le symbole d'un caiss

Pagina 8 - THIS APERTURE

Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten über den sie das Produkt erworben haben, oder besuchen sie unsere Hompa

Pagina 9

GENERAL VIEW Figure 3 - F734-E Series Terminals Overview B E D C A F Key: A) Laser beam output window B) Multi-function LED C) Reset key

Pagina 11

INTRODUCTION 11 INTRODUCTION 1.1 TERMINAL DESCRIPTION Two different models of this terminal are provided: Formula 734-E: communicates with the hos

Pagina 12 - Information for the User

Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy F734-E Series Terminals Ed.: 07/2010

Pagina 13 - PATENTS

F734-E SERIES TERMINALS 1 1.1.2 F734-E/RF The F734-E/RF terminal is a lightweight, pocket-sized and fully programmable radio frequency terminal. It s

Pagina 14 - WEEE COMPLIANCE

INTRODUCTION 1The F734-E series terminals have a backlit LCD graphic display of 16 characters by 4 lines plus a line in the upper part of the display

Pagina 15

F734-E SERIES TERMINALS 1 DS for Formula™ uses a «C» standard ANSI compiler, integrated with special libraries, operating in an MS-DOS environment and

Pagina 16

INTRODUCTION 11.4 PACKAGE CONTENTS The F734-E terminal package includes: − n. 1 F734-E terminal complete with batteries; − n. 1 user's manual

Pagina 17 - GENERAL VIEW

F734-E SERIES TERMINALS 1  NCK RS485 Network/PC connection kit  FBK73X-E Battery Kit NiMh F734-E  FBS73X-E Battery Kit NiMh F734-E (5 pcs pack)

Pagina 18

CONNECTIONS 22 CONNECTIONS 2.1 CRADLE To make the F734-E series terminal operative, it is necessary to insert it into the Formula 951 Transceiver C

Pagina 19 - 1 INTRODUCTION

F734-E SERIES TERMINALS 2 2.2 CONNECTION TO THE HOST COMPUTER CAUTION Before proceeding with this phase, make sure that both the computer and the t

Pagina 20 - 1.1.2 F734-E/RF

CONNECTIONS 2A B C D Figure 8 - RS232 Multi Cradle Connection Key: A) Host computer B) Serial cable C) Multi-cradle F950/4 D) Power supply NOTE Th

Pagina 21 - 4 LINES 16 CHARS

F734-E SERIES TERMINALS 2 2.2.2 Connection with Eavesdrop Interface The cable Kit 94A054030 provides two cables; one for Eavesdrop connections and o

Pagina 22

CONNECTIONS 22.2.3 RS485 Connection The RS485 line allows connecting several terminals to a single RS232 line by means of a network (see the "Fo

Pagina 23 - 1.5 ACCESSORIES

CONTENTS REFERENCES ...v Conventions...

Pagina 24

F734-E SERIES TERMINALS 2 FDB CA EFigure 10 - RS485 Connection Key: A) Host computer B) Formula 902 T-box C) Formula 904/N Interconverter D) Sin

Pagina 25 - 2 CONNECTIONS

CONNECTIONS 22.2.4 RF Connection The RF connection allows the F734-E/RF terminal to communicate with the host via radio frequency using the STARGATE™

Pagina 26 - 2.2.1 RS232 Connection

F734-E SERIES TERMINALS 2 2.3 CONNECTION CABLE Several types of cables are provided depending on the computer and on the connection. The following ca

Pagina 27

CONNECTIONS 2The black flat cable allowing the Modem connection has the following pinout: 1 2 4 Cradle side RJ45 245DB25 side25-pin D-sub (male) 37M

Pagina 28

F734-E SERIES TERMINALS 3 3 USE AND OPERATION The F734-E and F734-E/RF are lightweight, pocket-sized and fully programmable terminals with 512 KB (

Pagina 29 - 2.2.3 RS485 Connection

USE AND OPERATION 3 ARROW KEYS: only available for the application when not in “Select or Data Edit” mode. SCAN KEY: activates the laser for barcode

Pagina 30 - Figure 10 - RS485 Connection

F734-E SERIES TERMINALS 3 display’s contrast increases to the allowed maximum, and then returns to 0 value. NUMERIC KEYS: allow the entry and display

Pagina 31 - 2.2.4 RF Connection

USE AND OPERATION 33.2 BARCODE SCANNING When reading a barcode point the terminal laser beam at the code from an appropriate distance and simultaneou

Pagina 32 - 2.3 CONNECTION CABLE

F734-E SERIES TERMINALS 3 3.3 DELETING THE APPLICATION PROGRAM This procedure allows deleting application programs developed with DS for Formula™.

Pagina 33 - Twisted Pair

USE AND OPERATION 33.4 DOWNLOADING DATA TO HOST Data can be downloaded from the terminal to the host PC in different ways, depending on the applicat

Pagina 34

6 TECHNICAL FEATURES...28 GLOSSARY...30

Pagina 35

F734-E SERIES TERMINALS 4 4 MAINTENANCE NOTE Rechargeable battery packs (NiCd/NiMh) are not initially charged. Therefore the first operation to per

Pagina 36

MAINTENANCE 4 NOTE During the battery recharge the color of the LED positioned on the cradle changes from red to green. If using the NiCd battery pac

Pagina 37 - 3.2 BARCODE SCANNING

F734-E SERIES TERMINALS 4 4.2 REPLACING THE BATTERIES CAUTION Before proceeding, ensure that the terminal is switched off and that the data it con

Pagina 38 - ErasPrgFlash

MAINTENANCE 4 CAUTION Before inserting the battery pack into the terminal, ensure the battery polarity matches with the one indicated within the case

Pagina 39

F734-E SERIES TERMINALS 4 4.3 CLEANING THE TERMINAL Clean the terminal from time to time with a slightly damp cloth. Do not use alcohol, corrosive p

Pagina 40 - 4 MAINTENANCE

TROUBLESHOOTING 55 TROUBLESHOOTING PROBLEM CAUSE REMEDY Flat batteries. Recharge terminal. When the <SCAN> button is pressed the terminal d

Pagina 41

F734-E SERIES TERMINALS 6 6 TECHNICAL FEATURES F734-E F734-E/RF Optical Features Light source Laser-scanner; VLD source; 630-680nm Scan rate 35±5

Pagina 42 - 4.2 REPLACING THE BATTERIES

TECHNICAL FEATURES 6Environmental Features Electrostatic charges IEC 801-2 Drop resistance IEC 68-2-32 up to 1 m (39 in) onto concrete Laser safety

Pagina 43 - CONTACTS

GLOSSARY Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in binary form. The general format of a

Pagina 44 - 4.3 CLEANING THE TERMINAL

Host A computer that serves other terminals in a network, providing services such as network control, database access, special programs, supervisory

Pagina 45 - 5 TROUBLESHOOTING

REFERENCES CONVENTIONS This manual uses the following conventions: “User” or “Operator” refers to anyone using a F734-E Terminal. “Device” refers

Pagina 46 - 6 TECHNICAL FEATURES

INDEX A Accessories; 5 Application Development Programs; 3 B Barcode Scanning; 19 C Connections; 7 Connection Cable; 14 Connection with Eavesdrop I

Pagina 47

Datalogic Mobile S.r.l. 07Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, d

Pagina 48 - GLOSSARY

F734-E Series TerminalsUser's Manual©2001 - 2010 Datalogic Mobile S.r.l.01/10822000114 (Rev. E)www.mobile.datalogic.comDatalogic Mobile S.r.l.Via

Pagina 49

SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection or repair on the terminal. The user is responsible for

Pagina 50

LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. F734-E Laser beam output windo

Pagina 51

F734-E/RF Laser beam output window AVOID EXPOSURELASER LIGHT IS EMITTED FROMTHIS APERTURE N2468LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASE

Pagina 52

ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your te

Comentarios a estos manuales

Sin comentarios